潮牌酒店设计方案.pptx

上传人:风**** 文档编号:1100740 上传时间:2024-05-07 格式:PPTX 页数:83 大小:28.27MB
下载 相关 举报
潮牌酒店设计方案.pptx_第1页
第1页 / 共83页
潮牌酒店设计方案.pptx_第2页
第2页 / 共83页
潮牌酒店设计方案.pptx_第3页
第3页 / 共83页
潮牌酒店设计方案.pptx_第4页
第4页 / 共83页
潮牌酒店设计方案.pptx_第5页
第5页 / 共83页
点击查看更多>>
资源描述

1、The Unofficial Hotelyabu pushelberg1 00%SD PresentationAugust 1 1 th,2021conceptmise en scenea hotel experience that sets the stage.2with cinematic lighting that creates a mood and sets the toneconceptmise en scene3conceptmise en sceneconceptmise en scenewhere the characters are absorbed into scenes

2、 set with bold,saturated colors4for the characters to make it what they want.conceptthe characters5characters the it girl26 years oldhere to shop and explore6charactersculinary artist30 years old here for hobby7characters the inventor38 years oldhere for work or workcation8characters femme fatale31

3、years old here to observe9designed by YABU PUSHELBERG produced by PANGLANG GROUPscreen writing by YABU PUSHELBERG production by TEAM CThe Unofficial HotelGROUND FLOOR11character ground floorShe wanders down the street and disappears behind a set of double doors.you follow after her.12ground floor pl

4、anceiling heights and overall condition of structural beams (locations)detailed photos of elevator enclosure,elevator interior,entry sequencegeneral note-are there any structural or mechanical elements that are not shown in the base drawing(grey hatch)that must remain and will affect the planning st

5、rategy of this plan?13ground floor corridor14ground floor corridor15ground floorcorridor|paletteglasslarge format terrazzo ceiling finishffe upholstery trim detailsffe oil rubbed bronzesmall format terrazzosquare metalmesh16ground floor factory17ground floor warehouse18ground floor warehouse19ground

6、 floor warehouse20ground floor warehouse21ground floor warehouse|palettefloor terrazzofloor accent terrazzometal kitchen+detail ceiling+wall plaster wall panelffe upholsteryffe accent upholstery ffe stone22the inventor sixth floorYou know him only as the Inventor.his office is filled with inspiratio

7、n from the past and notions of the future.23sixth floorplanning diagram24floor to ceiling heights structural beams are very low-check to confirmglazing condition perimeter on 6th floor is different than on 7th floorceiling heights corridorsblue bubble walls are locations of shafts that run verticall

8、y through building-please check their location and if possible,which ones can be removed or modified in plan(re-sized,perimeter enclosure)-same general location on 6th and 7th floorthere is a pipe that apparently cannot be removed that runs vertically through this floor(and 7th floor)please check if

9、 there are any additional pipes like this on the floorplate that is part of our scope.We are confident that there might be more situations like this.general note-are there any structural or mechanical elements that are not shown in the base drawing(grey hatch)that must remain and will affect the pla

10、nning strategy of this plan?check ceiling heights to confirm plausibility of design shown in render-particularly at structural elements ceiling height drops to 2300mm or even less at some points.if any structural element drops below 2500mm should be marked6th Floorself check-inexcitement builds as y

11、ou pass through the glowing entry to his office.14Planself check-inceiling height and condition of perimeter15elevator lobby condition in plan,elevations and ceiling (in addition to elevator cab)6th Floorself check-in166th Floorself check-in|palettestone floormetal portalsceiling special finish meta

12、l mesh17you see him sitting in the lounge sipping his morning espresso while sketching new designs.sixth floorretail,bar&loungesixth floorretail,bar&lounge26sixth floorretail,coworking&lounge27carpetwall fabric metal portals ffe woodffe painttinted mirrorffe leather ffe stonesixth floorretail,cowork

13、ing&lounge|palette28sixth floor feature stairsteps lead you up towards a whole new world above.29sixth floorfeature stair&bar30sixth floorgrab-n-go bar|day31sixth floor bar|night32sixth floorfeature stair&bar|palettestone floormillwork metal stair enclosure stair paintffebar metal33sixth floor corri

14、dor34sixth floorcorridor|palettestone floorceiling metalwall metal ffedigital screen35you take your final bow and exit the wings to journey backstage.6th Floor elevator cab296th Floor elevator cab306th Floorelevator cab|palettestone floortinted mirrormetal meshmetal detailing31Publicbathroomsyou sli

15、p behind the mainstage into a mirrored hall.you check yourself in the mirror before the next curtain call46Publicbathrooms47metal detailingplaster wall high gloss ceramicfloor tilered tinted mirrorPublicbathroom I palette487TH FLOOR36Giving the public a glimpse in to his madness,his most controversi

16、al experiments remain behind closed doors.the inventor seventh floor37As the wall slides shut he disappears into his thinking chamber-imagining the world in ways unlike any other.seventh floor meeting spaces38seventh floorplanning diagram39floor to ceiling heights structural beams are very low-check

17、 to confirmglazing condition perimeter on 6th floor is different than on 7th floorceiling heights corridorsthere is a pipe that apparently cannot be removed that runs vertically through this floor(and 7th floor)please check if there are any additional pipes like this on the floorplate that is part o

18、f our scope.We are confident that there might be more situations like this.general note-are there any structural or mechanical elements that are not shown in the base drawing(grey hatch)that must remain and will affect the planning strategy of this plan?blue bubble walls are locations of shafts that

19、 run vertically through building-please check their location and if possible,which ones can be removed or modified in plan(re-sized,perimeter enclosure)-same general location on 6th and 7th floorcheck ceiling heights to confirm plausibility of design shown in render-particularly at structural elemen

20、ts ceiling height drops to 2300mm or even less at some points.if any structural element drops below 2500mm should be markedseventh floor meeting spaces40seventh floormeeting spaces&theatre41seventh floormeeting spaces|closed42seventh floor meeting spaces43seventh floormeeting spaces|palettebrushed m

21、etallic finishffe fabric painttinted mirrorterrazzo floor millwork wallstextured glass panel44seventh floor theatre45seventh floor theatre46seventh floor theatre47seventh floormeeting spaces&classroom48seventh floor meeting spaces49seventh floor classroom50seventh floorclassroom|closed51seventh floo

22、rmeeting spaces&classroom|palettemetal meshmetallic finishcarpetffe leatherffe wood finish52ROOFTOP BAR53femme fatalefifty fourth floorThrough the sheer and spotlights,she moves into the last moment of suspense.54fifty fourth floor sky bar55fifty fourth floor planning diagramfire egress stairs,can t

23、hese be used for circulation purposes-they cannot be punctured to allow for natural lighting in them?56general note-are there any structural or mechanical elements that are not shown in the base drawing(grey hatch)that must remain and will affect the planning strategy of this plan?fifty fifth floorp

24、lanning diagram57fifty fourth floor sky bar58fifty fourth floor sky bar59fifty fourth floor sky bar|palettepolished epoxy floormetal curtain wall claddingwood wall millworkglass brickbronze metal millwork/rigging structuresofa upholsteryrigging rope screenmarble barbarstool upholstery60GUEST SUITE61

25、guestrooms spiritedsuspendedguest suites composed groundedguest suite backstage62to a room thats youthful refinement beckons you to stay.guest suite backstage63guest suiteplanning diagramdesk/vanitylounge sofacoffee bar&sanitizing unitTVdrawer&safecloset&storage luggagesinktubshowertoiletthis is one

26、 of those blue bubble shafts referred to in previous plans-unfortunately it projects into the suite(shown in blue dashed line)64can this be moved,changed in order for the plan to work-otherwise the circulation will have to be re-thoughtgeneral note-are there any structural or mechanical elements tha

27、t are not shown in the base drawing(grey hatch)that must remain and will affect the planning strategy of this plan?check ceiling heights to confirm plausibility of design shown in render-particularly at structural elements ceiling height drops to 2300mm or even less at some points.if any structural

28、element drops below 2500mm should be markedguest suite bedroom65guest suite bedroom66guest suite bedroom67guest suite bedroom|palettesofa upholstery mirrorshelving metal muralbed upholsteryplasterwood flooringmetal mesh screensmetal screen framerug68guest suite ensuite69guest suite ensuite70guest suite ensuite|palettefloor terrazzo perimeter wall stoneplumbing fixtures ffe stoneshower wall metal71THANK YOU72

展开阅读全文
相关资源
相关搜索
资源标签

当前位置:首页 > 建筑施工 > 施工组织方案

版权声明:以上文章中所选用的图片及文字来源于网络以及用户投稿,由于未联系到知识产权人或未发现有关知识产权的登记,如有知识产权人并不愿意我们使用,如有侵权请立即联系:2622162128@qq.com ,我们立即下架或删除。

Copyright© 2022-2024 www.wodocx.com ,All Rights Reserved |陕ICP备19002583号-1 

陕公网安备 61072602000132号     违法和不良信息举报:0916-4228922